DS2690 Digital I/O Board

MultiCompact I/O board for vehicle body scenarios

The DS2690 is used in SCALEXIO hardware-in-the-loop simulators for signal measurement as well as signal generation. It provides digital I/O channels, such as Digital In, PWM In, Digital Out, and PWM Out. 

Application Area

The DS2690 Digital I/O Board is the tailored SCALEXIO solution for hardware-in-the-loop (HIL) simulation of body electronics ECUs. Vehicle body applications such as electric window lift and windscreen wipers require many high-current digital I/O channels, as well as the ability to simulate failures. Together with a SCALEXIO system, the DS2690 is galvanically isolated.

Key Benefits

The DS2690 offers a large number of dedicated digital I/O channels for signal generation and measurement. Their supported I/O functionalities cover exactly the ones needed for body electronic ECUs. Real loads can be connected to each channel individually. An onboard failure routing unit (FRU) enables failure simulation on all channels.

I/O Functionality

The DS2690 offers digital channels that are either predefined for signal measurement or signal generation, or can be individually configured. Channels for signal measurement and generation are usable as

  • Digital In
  • PWM In or Digital Out
  • PWM Out

The signal types and channel bundling are configured with ConfigurationDesk.

Real Loads for Real Currents

Testing ECUs under realistic circumstances sometimes requires real currents, so real loads can be connected externally. Substitute loads are available internally as well.

Parameter Specification
General
  • Multifuse for electrical safety
  • Channels bundling to increase the continuous current
Signal measurement (Digital In 2)
  • 10 channels
  • Measurement range 0 ... 60 V
  • Max. 6 A per channel
  • Substitute loads pluggable, up to 2 W per measurement channel
  • Real loads can be wired externally
  • FIU via high-current failrail
Signal generation (Digital Out 2)
  • 10 channels
  • Configurable as low-side/high-side switch or push/pull
  • Low-side = GND
  • High-side = external reference for each channel
  • Voltage range high-side: 5 ... 60 V
  • Current range -80 ... +80 mA
  • FIU via low-capacitance failrail
Signal measurement or generation (Digital In/Out 1)
  • 10 channels
  • FIU via low-capacitance failrail
  Digital In
  • Measurement range 0 ... 60 V
  • Max. 100 mA per channel
  • Substitute loads pluggable, up to 2 W per measurement channel
  • Real loads can be wired externally
Digital Out
  • Configurable as low-side/high-side switch or push/pull
  • Low-side = GND • High-side = external reference for each channel
  • Voltage range high-side: 5 ... 60 V
  • Current range -80 ... +80 mA
Fault simulation
  • Onboard failure routing unit (FRU)
  • Signal forwarding to central FIU
  • Based on relays
  • Available for each channel
Internal communication interface
  • IOCNET
Physical data Physical size
  • 402 x 100 x 58 mm (15.8 x 3.9 x 2.3 in)
  • Requires 3 slots
Voltage supply
  • 24 V
Typical power consumption
  • 18 W

  • SCALEXIO Product Information, PDF, English, 16194 KB
Product Information Support Contact Information

Drive innovation forward. Always on the pulse of technology development.

Subscribe to our expert knowledge. Learn from our successful project examples. Keep up to date on simulation and validation. Subscribe to/manage dSPACE direct and aerospace & defense now.

Enable form call

At this point, an input form from Click Dimensions is integrated. This enables us to process your newsletter subscription. The form is currently hidden due to your privacy settings for our website.

External input form

By activating the input form, you consent to personal data being transmitted to Click Dimensions within the EU, in the USA, Canada or Australia. More on this in our privacy policy.